Structural engineering and concrete design office

Structural study for an opening in a load-bearing stone wall near Cannes
Near Cannes (06), our Cannes office produced the detailed design for opening a load-bearing stone wall in a house and widening an existing opening. The solution: two steel beams, an HEB 200 and an HEB 180, resting on two reinforced-concrete columns built into the wall and on a UPN 180 steel column. The work was carried out by OMPT Groupe from our construction drawings.

On the ground floor of a house near Cannes, the owners wanted to join two rooms into one large living space. Between them stood a load-bearing stone wall, with an arched opening and a pier (the section of wall between two openings). On the side, an existing opening also had to be widened. Above, an existing reinforced-concrete ring beam, to be kept, carries the upper floor.
What solution for opening this stone wall?
A stone wall cannot be cut like a concrete-block wall. The stones vary in size and the mortar binding them is often old: a beam cannot be set directly on it. So our engineers designed two new bearings: two 20 × 20 cm reinforced-concrete columns (with 4 HA 10 bars and HA 6 links), cast in pockets cut into the stone and keyed into the existing wall.
On these two columns rests an HEB 200 steel beam (an H-shaped section, in S275 steel), slid under the retained reinforced-concrete ring beam. For the widened opening, a second HEB 180 beam connects to the first with two angles and six grade 8.8 M16 bolts. Its other end rests on a UPN 180 steel column, packed on a reinforced-concrete pad and anchored into the masonry.
The two beams are brought into contact with the existing ring beam and tie beam by packing wedges, then by concrete packing at the top of the columns. The house thus keeps a continuous load path: from the upper floor down to the walls and foundations.
What did the engineering office provide?
OMPT Structure's brief covered the design of the beams, columns and connections to the Eurocodes (the European standards for structural design), taking into account that the building is existing. It resulted in a set of five construction drawings: general notes and assumptions, plan view, elevations of the two walls, section and base of the reinforced-concrete columns, connection of the two beams, column head, plates, bar bending and propping principle.
The drawings also set out the order of the work, step by step: propping the floor on both sides of the wall; casting the columns one at a time, letting the concrete harden before moving to the next; installing and packing the HEB 200 beam; building the pad, installing the UPN 180 column and the HEB 180 beam; load transfer with the wedges; demolishing the wall between the columns; gradual removal of the props while checking cracks and deflection. The work was then carried out by OMPT Groupe from these drawings.
To find out more, read our article: Opening a stone wall: special precautions
Your structural engineering office in Cannes and Nice
Do you want to open a load-bearing wall, join two rooms or widen an opening in a stone house?
From our offices in Cannes and Nice, OMPT STRUCTURE carries out:
- structural feasibility studies for your project;
- structural diagnostics;
- detailed design for openings in load-bearing walls, stairwell openings, floor and roof-structure strengthening, and all other structural alterations;
- studies for extensions, raised storeys and new builds.
We work from Monaco to Saint-Tropez, in the Alpes-Maritimes (06) and the Var (83), from our offices in Cannes and Nice.